EnviDAQ 9410
4-Slot Sub-Controller Based On RS-485 (Compatible with ADAM 5000/485)
Main Features
- Easy to install and networking RS-485 communication
- Each system has 4 slot, Max can support 128 I/O point
- Support various software including Windows DLL driver, OCX driver, OPC server and HMI/SCAPA software driver.
- With surge protection, avoid system to be damaged by dangerous voltage and power transients
- Can use one R-8510 repeater to expand network, each system can have Max 256 R-9000 unit, max transmit distance can reach 10km
General Aspects
EnviDAQ-9410 , a trademark of Envitech Europe,use EIA RS-485 communication protocol. This protocol is the standard which has been widely used in industrial field balancing, two-way transmit. RS-485 has the advantage of further transmitting distance, higher transmitting speed, very suitable for industrial application.
Main Specifications
- CPU 16 Micro processor
- I/O model capacity: 4
- Built-in watchdog
- Power consumption: 1.0W
- Network Communication: RS-232or RS 485(2-wire) to mainframe
- Max communicate distance: 4000 feet(1.2km)
- Command format: ASCII command/response protocol
EnviDAQ 9420
4-Slot Sub-Controller Based On Ethernet
Main Features
- ARM 32-bit RISC CPU
- 10/100 base-T automatically check high speed communication terminal
- Support Modbus/TCP communication protocol, easy to integrate
- Support UDP event dealing function
- Can transmit 100M without any repeater
- 8 I/O slot can support128 point data monitor
- Build-in system auto-reposition watchdog
- Provide ActiveX driver for user developing
General Aspects
EnviDAQ-9420, a trademark of Envitech Europe, is an I/O system based on Ethernet. It communicate distance can reach 100M without repeater. Users can configure through Ethernet and allow 8 PC visit data at the same time.
Main Specifications
- CPU: 32-bit RISC CPU
- I/O model capacity: 4 slot
- Memory: 4MB RAM 512KB Flash ROM
- Operating system: real-time OS
- CPU power consumption: 5.0W
- Interface: RS-485
- EtheCommunication protocol: Modbus/TCP,TCP,UDP,IP,ARP
EnviDAQ 9810
8-Slot Sub-Controller Based On RS-485 (Compatible with ADAM 5000/485)
Main Features
- Easy to install and networking RS-485 communication
- Each system has 8 slot, Max can support 128 I/O point
- Support various software including Windows DLL driver, OCX driver, OPC server and HMI/SCAPA software driver.
- With surge protection, avoid system to be damaged by dangerous voltage and power transients
- Can use one R-8510 repeater to expand network, each system can have Max 256 R-9000 unit, max transmit distance can reach 10km
General Aspects
EnviDAQ-9810, a trademark of Envitech Europe, like the EnviDAQ-9410 (but with 8 slot and not 4) use EIA RS-485 communication protocol. This protocol is the standard which has been widely used in industrial field balancing, two-way transmit. RS-485 has the advantage of further transmitting distance, higher transmitting speed, very suitable for industrial application.
Main Specifications
- CPU 16 Micro processor
- I/O model capacity: 8
- Built-in watchdog
- Power consumption: 4.0W
- Network Communication: RS-232or RS 485(2-wire) to mainframe
- Max communicate distance: 4000 feet(1.2km)
- Command format: ASCII command/response protocol
EnviDAQ 9820
8-Slot Sub-Controller Based On Ethernet (Compatible With ADAM 5000/TCP)
Main Features
- ARM 32-bit RISC CPU
- 10/100 base-T automatically check high speed communication terminal
- Support Modbus/TCP communication protocol, easy to integrate
- Support UDP event dealing function
- Can transmit 100M without any repeater
- 8 I/O slot can support128 point data monitor
- Build-in system auto-reposition watchdog
- Provide ActiveX driver for user developing
General Aspects
EnviDAQ-9820, a trademark of Envitech Europe, like the EnviDAQ-9810 is an I/O system based on Ethernet. It communicate distance can reach 100M without repeater. Users can configure through Ethernet and allow 8 PC visit data at the same time.
Main Specifications
- CPU: 32-bit RISC CPU
- I/O model capacity: 8 slot
- Memory: 4MB RAM 512KB Flash ROM
- Operating system: real-time OS
- CPU power consumption: 5.0W
- Interface: RS-485
- EtheCommunication protocol: Modbus/TCP,TCP,UDP,IP,ARP
EnviDAQ 9033
3 Channel RTD Input Module
Main Features
- Channel: 3
- Resolution: 16
- Input type: PT100 or Ni RTD
- Power consumption: 0.85W (typical); 1.0W (Max)
- Isolation voltage: 3000VDC
- Sampling rate: 10sample point/s (total)
General Aspects
The EnviDAQ-9033 , a trademark of Envitech Europe,is a 16-bit, 3-channel RTD input module that features programmable input range on all channels. This module is an extremely cost-effective solution for industrial solution for industrial measurement and monitoring applications. Its opto-isolated inputs provide 3000Vdc of isolation between the analog input and the module, protecting the module and peripherals from damage due to high input line voltage.
Main Specifications
- Input impedance: 2mΩ
- Band width: 13.1Hz@50Hz, 15.72Hz@60Hz
- Input connect method: 2-wire, 3-wire, 4-wire
- Accuracy: ±0.1% or higher
- Zero drift:±0.015 Celsius
- Full-range drift: ±0.01 Celsius
EnviDAQ 9017
8-Channel Analog Input Module
Main Features
- Extremely cost-effective solution for industrial measurement and monitoring applications
- Provides programmable input ranges on all channels
- Signal fidelity is maintained even under fault conditions that would destroy other multiplexers
- This module can withstand an input voltage of 70 Vp-p with ±15V supplies
- 16-bit, 8-channel analog differential input module that provides programmable input ranges on all channels
- Accepts millivolt inputs, voltage inputs and current input
Main Specifications
- Input range:±150mV,±500mV, ±1V, ±5V, ±10V, ±200mA
- Isolated voltage: 3000VDC
- Sampling rate: 10 sample point/s(total)
- Input impedance: 2MΩ
- Input connect method: 2-wire, 3-wire, 4-wire
- Power consumption: 1W (typical)1.25W (Max)
- Attention: the voltage between two input ports must be ≤±15V
EnviDAQ 9018
7-Channel Thermocouple Input Module
Main Features
- 16-bit, 7-channel thermocouple input module
- The module features programmable input range on all channels
- Accepts millivolt inputs, voltage inputs, current inputs and thermocouple input (J,K,T,R,S,E,B)
- The module forwards the data to host computer in engineering units
- An external CJC on the plug-in terminal is designed for accurate temperature measurement
Main Specifications
- Input type: mV, V, mA, thermocouple
- Input range:±15mV,±50mV, ±100mV, ±500mA, ±1V, ±2.5V, ±20mV
- Isolated voltage: 3000VDC
- Power consumption: 0.5W (typical), 0.63W (Max)
- Input impedance: 2MΩ
- Sampling rate: 10 sample point/s(total)
- Full range drift : ±25PPM/Celsius
EnviDAQ 9024
4-Channel Analog Output Module
Main Features
- Channel: 4-channel differential
- Resolution: 12-bit (plus sign bit)
- Output range: 0~+10V, 0~20mV, 4~20mA
- Power consumption: 1.4W (typical, 2.9W (Max)
- Isolated voltage: 3000VDC
General Aspects
EnviDAQ-9024 , a trademark of Envitech Europe,is a 4-channel analog output module. It receives its digital input through the RS-485 interface of the EnviDAQ-9421/9821 system module from the host computer. The format of the data is engineering unit. It then uses the D/A converter controlled by the system module to convert the digital data into output signals. You can specify slew rate and start up current through the configuration software. The analog output can also be configured as current or voltage through the software utility. The module protects your equipment from ground loops and power surges by providing opto-isolation of the D/A output and transformer based isolation up to 500 Vdc.
Main Specifications
- Output type: mV, V
- Accuracy: ±0.1% of full range (current output),0.2% of full range (voltage output)
- Resolution: 0.015% of full range
- Zero drift: voltage output: 30mV/Celsius,Current output: 0.2mV/Celsius
- Full-range temperature ratio: 25ppm/Celsius
- Programmable output slope: 0.125~128.0mA/s
- Current load impedance: 0~500Ω(source)
EnviDAQ 9051D
16-Channel DI Module With LED Display
Main Features
- Channel: 16 digital input channels
- Input voltage: 30V (Max)
- Circuit type : put up current 0.5mA (source)
- LED display(R-9051D): on input logic level 1,Off input logic level 0
Main Specifications
- Logic level: Logic level 0: +1V (Max); Logic level 1: +3.5V to 30V
- Accuracy: ±0.1% of full range (current output),0.2% of full range (voltage output)
- Power consumption: R-9051: 0.4W(typical);0.53W (Max); R-9051D: 0.5W(typical); 0.84W(Max)
EnviDAQ 9056D
16-Channel DO Module With LED Display
Main Features
- 16 digital output channels
- DO can act as open-collector transistor switches that allow EnviDAQ main unit control
- Option to use the switches to control solid-state relays
- LED display: on-input logic level 1,Off- input logic level 0
Main Specifications
- Operating voltage: 30V (Max)
- Digital output: open collector 30V (100mA Max load)
- Power consumption:R-9056D: 0.5W (typical) 0.84W(Max)
- Power consumption: each channel 450mΩ
- Output status maintain function
EnviDAQ 9069
8-Channel Power Relay Output Module With LED Disaply
Main Features
- Channel: 8 relay channels of A type
- Switches can be used to control the relays
- Power consumption: 0.25W (typical), 2.2W (Max)
- Built with LED indicator for status reading easily
- Can clear or keep output status when reset by adjusting a jumper
Main Specifications
- Contact power: AC: 250V@5A, DC: 30V@5A
- Electric breakdown voltage: 700VAC (50/60Hz)
- Relay connect time: 5ms
- Relay open time: 5.6ms
- Insulating resistance: 1000mΩ (500VDC)
- LED display: On: in operation, Off: off-working
EnviDAQ 9080
4-Channel Frequency/Counter Module
Main Features
- Channel: 4
- Max counter: 4,294,967,285(32-bit)
- Input frequency: frequency model: 0.3~1000Hz (Max); counter model: 5000Hz (Max)
- Model: counter (plus/minus, two-way) frequency
- Power consumption: 1.3W (typical) 1.5 (Max)
- Programmable digital noise filter: 8~65000ms
Main Specifications
- Input level: isolation or TTL level
- Min impulse band width: 500ms (frequency model), 100ms (counter model)
- Min input current: 2mA (isolated)
- Isolated input level: logic level 0: +1V (Max); logic level 1: +3.5V to 30 V
- TTL input level: logic level 0: 0V to 0.8V; logic level 1: 2.3Vto 5V
- Isolated voltage: 1000VRMS
- Counter assisted function: Initialization setting, high/low alarm set up, warning digital output switch, overflow flag